DceL H2-5000 Hydrogen (H2) Sensor High range (0-5000ppm), low CO cross-sensitivity, low profile, interchangeable with 4-series

Target Gas: Hydrogen (H2)

Package: DceL

Range: 0 - 5000 ppm

Output: 10 ± 5nA /ppm

T90 Response Time: < 40 seconds (Typically <25secs)

Interface/Pins: Pin / 3 pins

Bias: 0V

Warranty: 12 months

Key Features:

Fast response & recovery, robust environmental stability and low CO cross-sensitivity.

Detailed Description:

The DceL H2-5000 is a Hydrogen (H2) sensor in DceL format with 3 Pin interface. The DceL H2-5000 requires 0V bias. With a measurement range of 0-5000 ppm and an output of 10 ± 5nA /ppm, the DceL H2-5000 has a T90 response time of < 40 seconds (Typically <25secs) and a warranty period of 12 months. Key features of the DceL H2-5000 include; Fast response & recovery, robust environmental stability and low CO cross-sensitivity.

Common Applications:

  • Industrial Safety
  • Industrial General